Ref: JP87111
The SigNET AC AKR1 Waiting Room Induction Loop Kit with SigNET PDA200E Amplifier and APL Outreach Plate with 2x Phono/RCA is a powerful and very cost-effective induction loop kit, designed specifically for waiting rooms. The AKR1 includes the PDA200E amplifier, which can cover up to 200 square metres of open space.
The kit is Fully compliant with BS 7594, clause 10 A3 and BS EN 60118-4 when correctly installed and feature two balanced/unbalanced line level inputs. In addition, the system also features one microphone input with phantom power for electret microphones.
The AKR1 kit includes the PDA200E amplifier, APL outreach plate (paging system input) and an 'AFILS fitted' sticker.
SigNET AC AKR1 Waiting Room Induction Loop Kit Features
SigNET AC PDA200E Amplifier
- A powerful and very cost-effective induction loop amplifier designed to drive a perimeter loop of up to 200 square metres
- Fully compliant with BS 7594, clause 10 A3 and BS EN 60118-4 when correctly installed
- Also available in a wide range of kit formats - suitable for use in meeting rooms, waiting rooms, TV?lounges, health and fitness suites, churches, etc
- Up to 200 metres (metal free) coverage - ideal for most 'free space' applications
- Features TWO balanced/unbalanced line level inputs and one microphone input with phantom power for electret microphones
- Ideal for electrical contractors - no audio connectors or experience required
- Metal compensation control to improve intelligibility in rooms with high metal content
SigNET AC APL Outreach Plate with 2x Phono/RCA
- Accepts stereo phono line-level signals (usually from a stereo source such as a TV)
- Includes an on-board stereo phono to mono converter
- Can be connected to the balanced line level input of any audio system
- Fully cascadable - up to ten outreach plates can be daisy-chained to one balanced line level input
- Plates can be located at any convenient point on an installation
- Standard two-pair audio cable is ideal for most applications
- Network lengths of 100m easily achievable with no degradation of sound quality
- Built-in pre-amp, mixer and level controls included on all variants
- Overcomes the need for excessively long microphone and audio leads
- 12-32V dc operation
- +6dB overload capability
- Surface mountable on 25mm UK single gang back boxes
- Effectively acts as a multi-point distributed mixer with individual level controls
- Optional wall-mounting 'AFILS ACTIVE' and magnetic field strength indicators available for use with audio-frequency induction loop systems
SigNET AC AKR1 Waiting Room Induction Loop Kit Specifications
SigNET AC PDA200E Amplifier
- Induction Loop Type: Wall mounting, requires fixed mains wiring
- Coverage: 200m² approx.
- Inputs:
- 1x Microphone
- 2x Line/Outreach
- Indicators:
- Input level
- Power
- Compression
- Peak Current (3,2,1)
- Controls:
- Metal Compensation
- Input level
- Loop drive
Physical:
- Dimensions (W x H x D): 273 x 200 x 77mm
- Weight: 2.82kg
SigNET AC APL Outreach Plate
- Supply volts: 12 to 37V regulated DC
- Supply current: 6 to 11mA
- Input signal level: -10dBu to +6dBu
- Input gain control: ∞ to 10dB
- Input impedance: >1KΩ
- Signal to noise ratio: >71dB
- THD + noise: <0.03%
Physical:
- Dimensions (W x H): 85 x 85mm
- Weight: 0.125kg
SigNET AC AKR1 Waiting Room Induction Loop Kit Supplied With
- SigNET AC PDA200E Amplifier
- SigNET AC APL outreach plate (paging system input)
- 'AFILS fitted' sticker