Ref: JP105758
The SigNET AC PDA103S Domestic Loop Kit with SigNET PDA103 Amplifier and APL Outreach Plate contains everything you need to create a high quality domestic hearing loop system for bedrooms, living rooms, TV lounges and studies up to 50m² in size (7m x 7m). Designed to connect to TV sets using the amplifier's 'Outreach' connector via the APL plate and SCART lead supplied, alternatively the amplifier can be connected to TV sets using the amplifier's onboard Digital TOS-link connector.
SigNET AC PDA103S Domestic Loop Kit with SigNET PDA103 Amplifier and APL Outreach Plate Features
- Wall mountable hearing loop amplifier
- 50m² approximate coverage
- Includes everything you need to create a high-quality domestic hearing loop system for bedrooms, living rooms, TV lounges and studies up to 50m2 in size (7m x 7m)
- PDA103 amplifier includes a 3.5mm microphone input, a line level input, a digital 'TOS' link connector and an 'outreach' socket
- Designed to connect to TV sets using the amplifier's 'Outreach' connector via the APL plate and SCART lead supplied.
- Alternatively, the amplifier can be connected to TV sets using the amplifier's onboard Digital TOS-link connector and a separately available TOS-link cable. See main instructions for further details.
- Metal compensation control helps improve intelligibility in rooms with high metal content
- Adjustable mic, line level, 'digital' and 'outreach' controls.
- Drive (level) control allows the amplifier's output stage to be set-up to suit the exact characteristics of the application.
- State-of-the-art audio processor features an automatic gain control which compensates for poor microphone techniques and helps suppress loud noises, hisses and clicks
- Limit, Peak, Loop Fault and Power On indicators
- Designed to be wall-mounted using the keyholes provided
- Meets and exceeds the requirements of BS7594 and EN60118-4 when correctly installed
SigNET AC PDA103S Domestic Loop Kit with SigNET PDA103 Amplifier and APL Outreach Plate Specifications
SigNET AC PDA103 Amplifier
- Hearing Loop Type: Wall mountable. Plugtop mains lead supplied
- Rated supply voltage: 110 to 240Va.c. @ 50/60Hz
- Rated power consumption: 18W PSU
- Maximum RMS output current: 4A @ 1kHz
- Maximum RMS load voltage: 5.5V
- Coverage area using 0.5mm² loop cable (approx): 50m², i.e. rooms up to approx. 7m x 7m
- Recommended number of turns: Single turn
- Recommended loop conductor size: 0.5mm² @ < 50m loop length
- Frequency response -3dB: 120Hz to 5kHz as per BS EN 60118-4
- Input signal level: Mic: -60dB unbalanced; Line: -27dB stereo unbalanced; Outreach: -10dB balanced
- Input impedance: Mic: 1k ohm; Line: 100k ohm; Outreach: 20k ohm
- Microphone phantom power: 12Vd.c.
- Signal to noise ratio, A weighted: -62dB
- Optical TOS-link receiver: Up to 24 bit, 96kHz sampling
- AGC range (3dB change in output current), reference rated I/P voltage: 10dB
- AGC ratio: 20:1
- Amplifier mode: True current mode
- Sensitivity level controls:
- Mic
- Line
- Digital
- Outreach
- Metal Compensation
- Level (all rotary pot controls are screwdriver adjustable)
- LED Indicators:
- Limit (Red)
- Peak (Red)
- Loop Fault (Red)
- Power On (Green)
- Connectors:
- Mic (3.5mm mono jack socket)
- Line (3.5mm stereo jack socket)
- Digital
- Outreach (4-way pluggable screw terminal)
- DC In
- Loop (2-way pluggable screw terminal)
SigNET AC APL2 Outreach Plate with 2x Phono/RCA Inputs
- Supply volts: 12 to 37V regulated DC
- Supply current: 6 to 11mA
- Input signal level: -10dBu to +6dBu
- Input gain control: ∞ to 10dB
- Input impedance: >1KΩ
- Signal to noise ratio: >71dB
- THD + noise: <0.03%
Physical:
- Dimensions (W x H x D): 85 x 85 x 25mm
- Weight: 0.15kg
SigNET AC PDA103S Domestic Loop Kit with SigNET PDA103 Amplifier and APL Outreach Plate Supplied With
- 1x SigNET PDA103 hearing loop amplifier
- 1x SigNET APL Outreach Plate
- 1x 230Va.c. PL1/PSU1 plug-top power supply
- 1x Loop cable
- 1x 'Hearing Loop Fitted' sticker